AT Commands and S-Registers
4-173821-A2-GB20-40 January 1999
Table 4-2
(2 of 10)
3821
Plus
S-Registers
S4 Line Feed Character
Determines ASCII value used as the line feed character.
Enter a value from 0–127 for the line feed character.
Factory setting is 10 (ASCII line feed).
S5 Backspace Character
Determines ASCII value used as the backspace (Backspace key). This character moves the cursor to the left and erases
the previous character.
Enter a value from 0–127.
Factory setting is 08 (ASCII backspace).
S6 Blind Dial Pause
Determines how long (in seconds) the modem waits after going off-hook before dialing a telephone number if using result
code X0, X1, or X3.
Enter a value from 2–255 seconds.
The factory setting is 2 seconds.
NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.
S7 No Answer Timeout
Determines how long (in seconds) an originating modem waits before abandoning a call when no answer tone is
received.
Enter a value from 1–255 seconds.
The factory setting is 45 seconds.
NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.
S8 ‘,” Pause Time for the Dial Modifier
Determines how long (in seconds) the modem pauses when it encounters a comma (,) in the Dial command string.
Enter a value from 0–255 seconds.
The factory setting is 2 seconds.
NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.
S10 No Carrier Disconnect
Determines how long (in tenths of seconds) the modem allows the carrier signal to be Off before disconnecting the call.
Enter a value from 0–254 in 0.1 second increments. A value of 255 disables this register.
Factory setting is 20 (2 seconds).
NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.
S12 Escape Guard Time
Sets the value (in 20-millisecond increments) for the required pause before and after the escape sequence is issued. The
guard time prevents the modem from interpreting data as the escape sequence characters.
Enter a value from 0–255 in 20-millisecond increments. For example, the factory setting of 50 equals 1000 milliseconds or
one second. Factory setting is 50 (1 second).